Newly Developed Products

DM1000-正面1.jpg

DM1000

Din type power analyser according IEC 61000-4-30 class S

▶ Identification of installation errors (eg: CT wiring errors)

▶ True RMS measurements

▶ Measurements: VL-L, VL-N, I, In, Cos∅, Pf, total Pf, Hz, W, ∑W, Va, ∑Va,Var, ∑Var, import Kwh, export Kwh, import Kvarh ,

export Kvarh , VTHD , I-THD , 1-63th harmonic , system running hours , % voltage unbalance, % current unbalance , % system load

▶ 3 voltage and 4 current input (Measure or calculate the neutralcurrent)

▶ Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective

▶ Transients detection >25us, Detection of events >10ms

▶ Voltage flicker measurement, % system load

▶ Maximum, minimum and demand for U, I, P, Q, S in hours, days,months

▶ Real time clock with integrated backup battery

▶ Multi-tariffe energy measurement

▶ 4 quadrants energy measurement support bi-directional power monitoring includes measurement on 

   regenerative loads, 

   also monthly energy calculation

▶ 2 digital input and 2 relay output (alarm or remote control)

▶ RS485 communication: Modbus RTU

▶ Waveforms capture and phase diagram for voltage, current

▶ Voltage and current sag/swell and transient event capture.

▶ Alarm event log

▶ Micro SD for data logger (support 32GB, only for RPM95S)

▶ USB port(Type C) for data transfer (only for RPM95U)

▶ Built in 128M flash memory for event, transient and data logger

▶ Data recorded in standard excel file formats for further EN50160 analysis

▶ Additional functions by plugging in optional modules

▶ Large backlit screen

Company News

RPM90U_RPM95S-00.png

DM400  

Din type power analyser according IEC 61000-4-30 class S

▶ True RMS measurements

▶ For single-phase, two-phase, three-phase system

▶ Measurements: VL-L,VL-N,I,In,Hz,Pf,Hz,W,∑W,Va,∑Va,

   Var,∑Var,import Kwh, export Kwh, import Kvarh,export 

   Kvarh,V-THD,I-THD system running hours.

▶ 3 voltage and 3 current input (calculate the neutral current)

▶ Maximum, minimum and demand for U, I, P, Q, S in hours,

   days, months

▶ Voltage Input: 0-690 Vac, Current input: 1 or 5A CT selective

   or 10/20/30A(depend on order)

▶ Real time clock with integrated backup rechargeable battery

▶ 4 quadrants energy measurement support bi-directional

    power monitoring includes measurement on regenerative

    loads,also monthly energy calculation

▶ RS485 communication: Modbus RTU

▶ English, Chinese (traditional & simplied) or Other language

DM400-正面1.png

RPM95U/RPM95S

panel mounting quality analyser according IEC 61000-4-30 class A

▶ True RMS measurements

▶ For single-phase, two-phase, three-phase system

▶ Measurements: VL-L,VL-N,I,In,Hz,Pf,Hz,W,∑W,Va,∑Va,Var,

   ∑Var,import Kwh, export Kwh, import Kvarh,export Kvarh,

   V-THD,I-THD system running hours.

▶ 3 voltage and 3 current input (calculate the neutral current)

▶ Maximum, minimum and demand for U, I, P, Q, S in hours,

   days, months

▶ Voltage Input: 0-690 Vac, Current input: 1 or 5A CT selective 

    or 10/20/30A(depend on order)

▶ Real time clock with integrated backup rechargeable battery

▶ 4 quadrants energy measurement support bi-directional 

   power monitoring includes measurement on regenerative 

   loads, also monthly energy calculation

▶ RS485 communication: Modbus RTU

▶ English, Chinese (traditional & simplied) or Other language